How to connect the circuit breaker? How to wire the leakage circuit breaker?
When the leakage switch is connected, connect the upper line and the lower line. Pay attention to the position of the phase line (commonly known as the fire line) and the neutral line. Do not connect the wrong mark. Look at the mark on the switch. If there is no mark, connect the line to the left and the line to the right. It is important to note that the neutral wire taken by the electrical equipment cannot be taken from the upper end of the leakage switch, and part of it is taken from the lower end of the leakage switch. If this is done, the leakage switch will not close. To put it another way, if you use the phase line that passes through the leakage switch, you must use the zero line that passes through the leakage switch. The power-operated leakage switch is lightly pressed by the above test button, and the leakage switch should be tripped immediately, and then pressed once a month to confirm that the leakage protection function of the leakage switch is effective. Note: Pressing the test button frequently during power-on will affect the service life of the switch. The leakage circuit breaker is divided into single-phase line and three-phase line. Single-phase wiring is divided into four groups of wiring methods and multiple groups of wiring methods. See what you said is completely correct. As for your use of the C60 leakage circuit breaker, you can fully meet your above electrical use. C60 rated current range: 1A-63A. P = UI = 220V * 63A = 13860W. The total power of all the appliances above you will not exceed the rated power of the leakage circuit breaker, so the use is safe.
Related articles
-
Renewable energy, new energy
The current quick-break protection, as the name implies, refers to the current protection of the instantaneous action when the cable joint current changes or exceeds the preset protection value range.
-
Is the standard connection of the circuit breaker a left zero right fire?
The circuit breaker can protect the line at home. Once the line in the home fails, the circuit breaker can automatically trip, thereby reducing the accident loss. It can be said that the circuit break
-
What are the main technical parameters of the circuit breaker?
1 rated voltage (KV)Refers to the rated (line) voltage of the system when the circuit breaker is working normally. This is the nominal voltage of the circuit breaker. The circuit breaker should be abl
-
What are the main technical parameters of the circuit breaker?
1. Rated voltage (KV)Refers to the rated (line) voltage of the system when the circuit breaker is working normally. This is the nominal voltage of the circuit breaker. The circuit breaker should be ab
-
How does the circuit breaker work?
working principleThe circuit breaker generally consists of a contact system, an arc extinguishing system, an operating mechanism, a trip unit, a casing, and the like.When short-circuited, the magnetic
-
Is the circuit breaker an air switch?
A circuit breaker is a switching device that can close, carry and break current under normal circuit conditions, and can close and carry current under abnormal loop conditions (including short-circuit
-
How to connect the circuit breaker? How to wire the leakage circuit breaker?
As shown in the figure, the red is the fire line, the green is the zero line, the front is the leakage protection switch, and the rear is the circuit breaker (air switch).Through the leakage circuit b
-
How to choose miniature circuit breaker C type and D type
The miniature circuit breaker used for motor start should be D type, C type used for power distribution control and lighting, D type has a larger short-circuit segment multiple than C type.